Modbus Command Set

Modbus Mode Configuration

There is an RS485 communication interface respectively at the aerial plug of the controller and the aerial plug of the end interface board of the RealMan robotic arm. The two RS485 ports can be configured to standard ModbusRTU mode through the JSON protocol. Then the peripherals connected to the interface can be read or written through the JSON protocol.

  • Modbus supports switching between RTU and TCP modes. Please configure according to your needs.
  • Supports adding multiple ModbusTCP master configurations.

Add Modbus TCP Master add_modbus_tcp_master

  • Input Parameter
ParameterTypeDescription
add_modbus_tcp_masterstringAdd a new Modbus TCP master configuration.
master_namestringName of the TCP master.
ipintIP address of the TCP master.
portintPort number of the TCP master.
  • Output Parameter
ParameterTypeDescription
add_statebooltrue: Added successfully, false: Failed to add.
  • Code demo

Input

Add a new master with IP: 127.0.0.1, port: 502, and name: 123.

json
{"command":"add_modbus_tcp_master","master_name":"123","ip":"127.0.0.1","port":502}

Output

Added successfully:

json
{
    "command":"add_modbus_tcp_master",
    "add_state":true
}

Failed to add:

json
{
    "command":"add_modbus_tcp_master",
    "add_state":false
}

Update Modbus TCP Master update_modbus_tcp_master

  • Input Parameter
ParameterTypeDescription
add_modbus_tcp_masterstringAdd a new Modbus TCP master configuration.
master_namestringName of the TCP master.
new_namestringNew name to be modified.
ipintIP address to be modified.
portintPort number to be modified.
  • Output Parameter
ParameterTypeDescription
update_statebooltrue: Updated successfully, false: Failed to update.
  • Code demo

Input

Update the master name to: 321.

json
{"command":"update_modbus_tcp_master","master_name":"123","new_name":"321","ip":"127.0.0.1","port":502}

Output

Updated successfully:

json
{
    "command":"update_modbus_tcp_master",
    "update_state":true
}

Failed to update:

json
{
    "command":"update_modbus_tcp_master",
    "update_state":false
}

Delete Modbus TCP Master delete_modbus_tcp_master

  • Input Parameter
ParameterTypeDescription
delete_modbus_tcp_masterstringDelete the specified TCP master.
master_namestringName of the TCP master to be deleted.
  • Output Parameter
ParameterTypeDescription
delete_statebooltrue: Deleted successfully, false: Failed to delete.
  • Code demo

Input

Delete the TCP master with the name 123.

json
{"command":"delete_modbus_tcp_master","master_name":123}

Output

Deleted successfully:

json
{
    "command": "delete_modbus_tcp_master",
    "delete_state": true
}

Failed to delete:

json
{
    "command": "delete_modbus_tcp_master",
    "delete_state": false
}

Query Modbus Master List get_modbus_tcp_master_list

  • Input Parameter
ParameterTypeDescription
get_modbus_tcp_master_liststringQuery the list of TCP masters.
page_numintPage number (omit this parameter when querying all).
page_sizeintPage size (omit this parameter when querying all).
vague_searchstringFuzzy search (pass this parameter for fuzzy query).
  • Output Parameter
ParameterTypeDescription
get_modbus_tcp_master_liststringQuery the list of TCP masters.
total_sizeintTotal number of items in the list.
listobjectDetailed information of TCP masters.
  • Code demo

Input

Query the current saved Modbus master list, page number: 1, page size: 10, fuzzy search for "file".

json
{"command":"get_modbus_tcp_master_list","page_num":1,"page_size":10,"vague_search":"file"}

Output

Successful query result:

json
{
    "command":"get_modbus_tcp_master_list",
    "total_size":2,
    "list":[
        {
            "master_name":"123",
            "ip":"192.168.1.18",
            "port":502
        },
        {
            "master_name":"321",
            "ip":"192.168.1.19",
            "port":502
        }
    ]
}

Failed query:

json
 {
    "command":"get_modbus_tcp_master_list",
    "get_state":false
}

Query Specified Modbus Master given_modbus_tcp_master

  • Input Parameter
ParameterTypeDescription
given_modbus_tcp_masterstringQuery the specified TCP master.
master_namestringName of the TCP master.
  • Output Parameter
ParameterTypeDescription
master_namestringName of the TCP master.
ipstringIP address of the TCP master.
portintPort number of the TCP master.
  • Code demo

Input

Query the TCP master with the name 123.

json
{"command":"given_modbus_tcp_master","master_name":"123"}

Output

Query successful:

json
{
    "command":"given_modbus_tcp_master",
    "master_name":"123",
    "ip":"192.168.1.18",
    "port":502
}

Query failed:

json
{
    "command":"given_modbus_tcp_master",
    "given_state":false
}

Modbus Status

Query Controller RS485 Mode get_controller_rs485_mode

  • Input Parameter
ParameterTypeDescription
get_controller_rs485_modestringQuery the controller RS485 mode.
  • Output Parameter
ParameterTypeDescription
get_controller_rs485_modestringQuery the controller RS485 mode.
controller_rs485_modeint0 represents default RS485 serial communication, 1 represents Modbus RTU master mode, and 2 represents Modbus RTU slave mode.
baudrateintBaud rate. (Currently supports 9600, 19200, 38400, 57600, 115200, 230400, 460800)
  • Code demo

Query the controller RS485 mode.

Input

json
{ "command": "get_controller_rs485_mode" }

Output

Feedback on the controller RS485 mode, as follows:

  • Current controller RS485 mode: 1;
  • Current controller RS485 baud rate: 460800.
json
{
    "command": "get_controller_rs485_mode",
    "controller_rs485_mode": 1,
    "baudrate": 460800
}

Query end of Tool RS485 Modeget_tool_rs485_mode

  • Input Parameter
ParameterTypeDescription
get_tool_rs485_modestringQuery the end of tool RS485 mode.
  • Output Parameter
ParameterTypeDescription
get_tool_rs485_modestringFeedback on the end of tool RS485 mode.
tool_rs485_modeint0 - represents Modbus RTU master mode, 1 - represents dexterous hand mode, 2 - represents gripper mode.
baudrateintBaud rate. (Currently supports 9600, 115200, 460800)
  • Code demo

Input

Query the end of tool RS485 mode.

json
{ "command": "get_tool_rs485_mode" }

Output

Feedback on the end of tool RS485 mode, as follows:

  • Current tool - end RS485 mode: 1;
  • Current tool - end RS485 baud rate: 460800.
json
{
  "command": "get_tool_rs485_mode",
  "tool_rs485_mode": 1,
  "baudrate": 460800
}

Configure Controller Communication Port RS485 Mode set_controller_rs485_mode

  • Input Parameter
ParameterTypeDescription
set_controller_rs485_modestringConfigure the controller communication port RS485 mode.
modeint0 represents default RS485 serial communication, 1 represents Modbus RTU master mode, and 2 represents Modbus - RTU slave mode.
baudrateintBaud rate. (Currently supports 9600, 19200, 38400, 57600, 115200, 230400, 460800)
  • Code demo

Input

Configure the port to ModbusRTU mode, as follows:

  • Configure the controller RS485 mode: 1;
  • Configure the controller RS485 baud rate: 115200.
json
{"command":"set_controller_rs485_mode","mode":1,"baudrate":115200}

Output

Configuration successful:

json
{
    "command": "set_controller_rs485_mode",
    "set_state": true
}

Configuration failed:

json
{
    "command": "set_controller_rs485_mode",
    "set_state": false
}

Configure end of Tool RS485 Mode set_tool_rs485_mode

  • Input Parameter
ParameterTypeDescription
set_tool_rs485_modestringConfigure the end of tool RS485 mode.
modeintCommunication port, 0 - set the end of tool RS485 port to RTU master, 1 - set the end of tool RS485 port to dexterous hand mode, 2 - set the end of tool RS485 port to gripper mode.
baudrateintBaud rate. (Currently supports 9600, 115200, 460800)
  • Code demo

Input

Configure the tool - end RS485 mode, as follows:

  • Configure the tool - end RS485 mode: 1;
  • Configure the tool - end RS485 baud rate: 115200.
json
{"command":"set_tool_rs485_mode","mode":0,"baudrate":115200}

Output

Configuration successful:

json
{
    "command": "set_tool_rs485_mode",
    "set_state": true
}

Configuration failed:

json
{
    "command": "set_tool_rs485_mode",
    "set_state": false
}

End of Tool and end of Controller RTU Modbus Protocol Commands

Read Coils read_modbus_rtu_coils

  • Input Parameter
ParameterTypeDescription
read_modbus_rtu_coilsstringRead coils.
addressintStarting address of the coils.
deviceintPeripheral device address.
numintNumber of coils.
typeint0 - controller - end Modbus master; 1 - tool - end Modbus master.
  • Output Parameter
ParameterTypeDescription
read_modbus_rtu_coilsstringRead coils.
dataintData read (not displayed if read fails).
read_stateboolRead result (not displayed if read is successful).
  • Code demo

Input

Read the coil status, as follows:

  • Read coil address: 10;
  • Read slave device number: 1;
  • Read coil quantity: 1;
  • Read port: 0.
json
{
    "command":"read_modbus_rtu_coils",
    "address":10,
    "device":1,
    "num":1,
    "type":1
}

Output

Read successful, as follows:

  • Read command: read_modbus_rtu_coils;
  • Read content: 1.
json
{
    "command": "read_modbus_rtu_coils",
    "data": [1]
}

Read failed:

json
{
    "command": "set_controller_rs485_mode",
    "read_state": false
}

Write Coils write_modbus_rtu_coils

  • Input Parameter
ParameterTypeDescription
write_modbus_rtu_coilsstringWrite coil command.
addressintStarting address of the coil.
deviceintPeripheral device address.
dataintContent to be written.
portint0 - end of controller Modbus master; 1 - end of tool Modbus master.
  • Code demo

Input

Write the coil status, as follows:

  • Write coil address: 10;
  • Write slave device number: 1;
  • Write coil content: 1, 0;
  • Write port: 0.
json
{
    "command":"write_modbus_rtu_coils",
    "address":10,
    "data":[1,0],
    "type":1,
    "device":1
}

Output

Write successful:

json
{
    "command": "write_modbus_rtu_coils",
    "write_state": true
}

Write failed:

json
{
    "command": "write_modbus_rtu_coils",
    "write_state": false
}

Read Discrete Inputs read_modbus_rtu_input_status

  • Input Parameter
ParameterTypeDescription
read_modbus_rtu_input_statusstringRead discrete input.
addressintStarting address.
deviceintPeripheral device address.
numintNumber of coils.
typeint0 - end of controller Modbus master; 1 - end of tool Modbus master.
  • Output Parameter
ParameterTypeDescription
read_modbus_rtu_input_statusstringRead discrete input.
dataintData read (not displayed if read fails).
read_stateboolRead result (not displayed if read is successful).
  • Code demo

Input

Read the discrete input status, as follows:

  • Read discrete input address: 10;
  • Read slave device number: 1;
  • Read discrete input quantity: 1;
  • Read port: 0.
json
{
    "command":"read_modbus_rtu_input_status",
    "address":10,
    "device":1,
    "num":1,
    "type":1
}

Output

Read successful:

json
{
    "command": "read_modbus_rtu_input_status",
    "data": [1]
}

Read failed:

json
{
    "command": "read_modbus_rtu_input_status",
    "read_state": false
}

Write Holding Registers write_modbus_rtu_registers

  • Input Parameter
ParameterTypeDescription
write_modbus_rtu_registersstringWrite holding registers.
addressintStarting address of the holding register.
deviceintPeripheral device address.
dataintContent to be written.
typeint0 - end of controller Modbus master; 1 - end of tool Modbus master.
  • Code demo

Input

Write data to the holding register, as follows:

  • Write holding register address: 10;
  • Write slave device number: 1;
  • Write holding register content: 15, 20;
  • Write port: 0.
json
{
    "command":"write_modbus_rtu_registers",
    "address":10,
    "data":[15,20],
    "type":1,
    "device":1
}

Output

Write successful:

json
{
    "command": "write_modbus_rtu_registers",
    "write_state": true
}

Write failed:

json
{
    "command": "write_modbus_rtu_registers",
    "write_state": false
}

Read Holding Registers read_modbus_rtu_holding_registers

  • Input Parameter
ParameterTypeDescription
read_modbus_rtu_holding_registersstringRead holding registers.
addressintStarting address.
deviceintPeripheral device address.
numintNumber of holding registers.
typeint0 - end of controller Modbus master; 1 - end of tool Modbus master.
  • Output Parameter
ParameterTypeDescription
read_modbus_rtu_holding_registersstringRead holding registers.
dataintData read (not displayed if read fails).
read_stateboolRead result (not displayed if read is successful).
  • Code demo

Input

Read data from the holding register, as follows:

  • Read holding register address: 10;
  • Read slave device number: 1;
  • Read holding register quantity: 5;
  • Read port: 0.
json
{
    "command":"read_modbus_rtu_holding_registers",
    "address":10,
    "device":1,
    "num":5,
    "type":1
}

Output

Read successful, read content: 1,2,3,4,5.

json
{
    "command": "read_modbus_rtu_holding_registers",
    "data": [1,2,3,4,5]
}

Read failed:

json
{
    "command": "read_modbus_rtu_holding_registers",
    "read_state": false
}

Read Input Registers read_modbus_rtu_input_registers

  • Input Parameter
ParameterTypeDescription
read_modbus_rtu_input_registersstringRead input registers.
addressintStarting address.
deviceintPeripheral device address.
numintNumber of input registers.
typeint0 - end of controller Modbus master; 1 - end of tool Modbus master.
  • Output Parameter
ParameterTypeDescription
read_modbus_rtu_input_registersstringRead input registers.
dataintData read (not displayed if read fails).
read_stateboolRead result (not displayed if read is successful).
  • Code demo

Input

Read data from the input register, as follows:

  • Read input register address: 10;
  • Read slave device number: 1;
  • Read input register quantity: 5;
  • Read port: 0.
json
{
    "command":"read_modbus_rtu_input_registers",
    "address":10,
    "device":1,
    "num":5,
    "type":1
}

Output

Read successful:

json
{
    "command": "read_modbus_rtu_input_registers",
    "data": [1,2,3,4,5]
}

Read failed:

json
{
    "command": "read_modbus_rtu_input_registers",
    "read_state": false
}

Controller TCP Modbus Protocol Commands

Read Coils read_modbus_tcp_coils

  • Input Parameter
ParameterTypeDescription
read_modbus_tcp_coilsstringRead coils.
addressintStarting address of the coils.
numintNumber of coils.
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Output Parameter
ParameterTypeDescription
read_modbus_tcp_coilsstringRead coils.
dataintData read (not displayed if read fails).
read_stateboolRead result (not displayed if read is successful).
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Code demo

Input

Use master_name to read the coil status, as follows:

  • Read coil address: 10;
  • Read slave device number: 1;
  • Read coil quantity: 1;
  • Host name: "123".
json
{
    "command":"read_modbus_tcp_coils",
    "address":10,
    "num":1,
    "master_name":"123"
}

Use ip + port to read the coil status, as follows:

  • Read coil address: 10;
  • Read slave device number: 1;
  • Read coil quantity: 1;
  • Read IP: "192.168.1.18";
  • Read port: 502.
json
{
    "command":"read_modbus_tcp_coils",
    "address":10,
    "num":1,
    "ip":"192.168.1.18",
    "port":502
}

Output

Use master_name to read successfully, as follows:

json
{
    "command": "read_modbus_tcp_coils",
    "data": [1],
    "master_name": "123"
}

Read failed, as follows:

json
{
    "command": "read_modbus_tcp_coils",
    "read_state": false,
    "master_name": "123"
}

Use ip + port to read successfully, as follows:

json
{
    "command": "read_modbus_tcp_coils",
    "data": [1],
    "ip":"192.168.1.18",
    "port":502
}

Read failed, as follows:

json
{
    "command": "read_modbus_tcp_coils",
    "read_state": false,
    "ip":"192.168.1.18",
    "port":502
}

Write Coils write_modbus_tcp_coils

  • Input Parameter
ParameterTypeDescription
write_modbus_tcp_coilsstringWrite coil command.
addressintStarting address of the coil.
dataintContent to be written.
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Output Parameter
ParameterTypeDescription
write_modbus_tcp_coilsstringWrite coil.
write_stateboolWrite result.
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Code demo

Input

Use master_name to write the coil status, as follows:

  • Write coil address: 10;
  • Write coil content: 1, 0;
  • Write host: "123".
json
{
    "command":"write_modbus_tcp_coils",
    "address":10,
    "data":[1,0],
    "master_name": "123"
}

Use ip + port to write the coil status, as follows:

  • Write coil address: 10;
  • Write coil content: 1, 0;
  • Write IP: "192.168.1.18";
  • Write port: 502.
json
{
    "command":"write_modbus_tcp_coils",
    "address":10,
    "data":[1,0],
    "ip":"192.168.1.18",
    "port":502
}

Output

Use master_name to write successfully:

json
{
    "command": "write_modbus_tcp_coils",
    "write_state": true,
    "master_name": "123"
}

Use master_name to write failed:

json
{
    "command": "write_modbus_tcp_coils",
    "write_state": false,
    "master_name": "123"
}

Use ip + port to write successfully:

json
{
    "command": "write_modbus_tcp_coils",
    "write_state": true,
    "ip":"192.168.1.18",
    "port":502
}

Use ip + port to write failed:

json
{
    "command": "write_modbus_tcp_coils",
    "write_state": false,
    "ip":"192.168.1.18",
    "port":502
}

Read Discrete Inputs read_modbus_tcp_input_status

  • Input Parameter
ParameterTypeDescription
read_modbus_tcp_input_statusstringRead discrete input.
addressintStarting address of the discrete input.
numintNumber of discrete inputs.
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Output Parameter
ParameterTypeDescription
read_modbus_tcp_input_statusstringRead discrete input.
dataintData read (not displayed if read fails).
read_stateboolRead result (not displayed if read is successful).
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Code demo

Input

Use master_name to read the discrete input status, as follows:

  • Read discrete input address: 10;
  • Read discrete input quantity: 1;
  • Read host: "123".
json
{
    "command":"read_modbus_tcp_input_status",
    "address":10,
    "num":1,
    "master_name": "123"
}

Use ip + port to read the discrete input status, as follows:

  • Read discrete input address: 10;
  • Read discrete input quantity: 1;
  • Write IP: "192.168.1.18";
  • Write port: 502.
json
{
    "command":"read_modbus_tcp_input_status",
    "address":10,
    "num":1,
    "ip":"192.168.1.18",
    "port":502
}

Output

Use master_name to read successfully:

json
{
    "command": "read_modbus_tcp_input_status",
    "data": [1],
    "master_name": "123"
}

Use master_name to read failed:

json
{
    "command": "read_modbus_tcp_input_status",
    "read_state": false,
    "master_name": "123"
}

Use ip + port to read successfully:

json
{
    "command": "read_modbus_tcp_input_status",
    "data": [1],
    "ip":"192.168.1.18",
    "port":502
}

Use ip + port to read failed:

json
{
    "command": "read_modbus_tcp_input_status",
    "read_state": false,
    "ip":"192.168.1.18",
    "port":502
}

Write Holding Registers write_modbus_tcp_registers

  • Input Parameter
ParameterTypeDescription
write_modbus_tcp_registersstringWrite holding register command.
addressintStarting address of the holding register.
dataintContent to be written.
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Output Parameter
ParameterTypeDescription
write_modbus_tcp_registersstringWrite holding register.
write_stateboolWrite result.
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Code demo

Input

Use master_name to write data to the holding register, as follows:

  • Write holding register address: 10;
  • Write holding register content: 15, 20;
  • Write host: "123".
json
{
    "command":"write_modbus_tcp_registers",
    "address":10,
    "data":[15,20],
    "master_name": "123"
}

Use ip + port to write the holding register status, as follows:

  • Write holding register address: 10;
  • Write holding register content: 15, 20;
  • Write IP: "192.168.1.18";
  • Write port: 502.
json
{
    "command":"write_modbus_tcp_registers",
    "address":10,
    "data":[15,20],
    "ip":"192.168.1.18",
    "port":502
}

Output

Use master_name to write successfully:

json
{
    "command": "write_modbus_tcp_registers",
    "write_state": true,
    "master_name": "123"
}

Use master_name to write failed:

json
{
    "command": "write_modbus_tcp_registers",
    "write_state": false,
    "master_name": "123"
}

Use ip + port to write successfully:

json
{
    "command": "write_modbus_tcp_registers",
    "write_state": true,
    "ip":"192.168.1.18",
    "port":502
}

Use ip + port to write failed:

json
{
    "command": "write_modbus_tcp_registers",
    "write_state": false,
    "ip":"192.168.1.18",
    "port":502
}

Read Holding Registers read_modbus_tcp_holding_registers

  • Input Parameter
ParameterTypeDescription
read_modbus_tcp_holding_registersstringRead holding register.
addressintStarting address of the holding register.
numintNumber of holding registers.
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Output Parameter
ParameterTypeDescription
read_modbus_tcp_holding_registersstringRead holding register.
dataintData read (not displayed if read fails).
read_stateboolRead result (not displayed if read is successful).
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Code demo

Input

Use master_name to read the holding register status, as follows:

  • Read holding register address: 10;
  • Read holding register quantity: 1;
  • Read host: "123".
json
{
    "command":"read_modbus_tcp_holding_registers",
    "address":10,
    "num":1,
    "master_name": "123"
}

Use ip + port to read the holding register status, as follows:

  • Read holding register address: 10;
  • Read holding register quantity: 1;
  • Write IP: "192.168.1.18";
  • Write port: 502.
json
{
    "command":"read_modbus_tcp_holding_registers",
    "address":10,
    "num":1,
    "ip":"192.168.1.18",
    "port":502
}

Output

Use master_name to read successfully:

json
{
    "command": "read_modbus_tcp_holding_registers",
    "data": [1],
    "master_name": "123"
}

Use master_name to read failed:

json
{
    "command": "read_modbus_tcp_holding_registers",
    "read_state": false,
    "master_name": "123"
}

Use ip + port to read successfully:

json
{
    "command": "read_modbus_tcp_holding_registers",
    "data": [1],
    "ip":"192.168.1.18",
    "port":502
}

Use ip + port to read failed:

json
{
    "command": "read_modbus_tcp_holding_registers",
    "read_state": false,
    "ip":"192.168.1.18",
    "port":502
}

Read Input Registers read_modbus_tcp_input_registers

  • Input Parameter
ParameterTypeDescription
read_modbus_tcp_input_registersstringRead input register.
addressintStarting address of the input register.
numintNumber of input registers.
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Output Parameter
ParameterTypeDescription
read_modbus_tcp_input_registersstringRead input register.
dataintData read (not displayed if read fails).
read_stateboolRead result (not displayed if read is successful).
master_namestringUse the Modbus master name in the list (either master_name or IP, if IP and port are available, they will be used preferentially).
ipstringIP address of the host connection (either master_name or IP, if IP and port are available, they will be used preferentially).
portintPort number of the host connection.
  • Code demo

Input

Use master_name to read the input register status, as follows:

  • Read input register address: 10;
  • Read input register quantity: 1;
  • Read host: "123".
json
{
    "command":"read_modbus_tcp_input_registers",
    "address":10,
    "num":1,
    "master_name": "123"
}

Use ip + port to read the input register status, as follows:

  • Read input register address: 10;
  • Read input register quantity: 1;
  • Write IP: "192.168.1.18";
  • Write port: 502.
json
{
    "command":"read_modbus_tcp_input_registers",
    "address":10,
    "num":1,
    "ip":"192.168.1.18",
    "port":502
}

Output

Use master_name to read successfully:

json
{
    "command": "read_modbus_tcp_input_registers",
    "data": [1],
    "master_name": "123"
}

Use master_name to read failed:

json
{
    "command": "read_modbus_tcp_input_registers",
    "read_state": false,
    "master_name": "123"
}

Use ip + port to read successfully:

json
{
    "command": "read_modbus_tcp_input_registers",
    "data": [1],
    "ip":"192.168.1.18",
    "port":502
}

Use ip + port to read failed:

json
{
    "command": "read_modbus_tcp_input_registers",
    "read_state": false,
    "ip":"192.168.1.18",
    "port":502
}